APC · Uninterruptible Power Supplies (UPSs)
APC SURT1000XLI-1 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 700 W 6 AC outlet(s)
- UPS topology: Double-conversion (Online)
- Output power capacity: 1 kVA
- AC outlet types: C13 coupler
- Power plug: C14 coupler
Pricing on request for federal, state, and local agencies.
Availability
Automatic internal bypass:
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Scalable runtime:
Allows additional run time to be quickly added as needed.
Intelligent battery management:
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries:
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown:
Automatically starts up the connected equipment upon the return of utility power.
Temperature-compensated battery charging:
Prolongs battery life by regulating the charge voltage according to battery temperature.
Manageability
Network manageable:
Provides remote power management of the UPS over the network.
InfraStruXure Manager Compatible:
Enables centralized management via the APC InfraStruXure Manager.
SmartSlot:
Customize UPS capabilities with management cards.
LED status indicators:
Quickly understand unit and power status with visual indicators.
Serial connectivity:
Provides management of the UPS via a serial port.
Adaptability
Plug-and-Play external batteries:
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible:
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Flash upgradeable firmware:
Install maintenance releases of firmware remotely using FTP.
Serviceability
User-replaceable batteries:
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-test:
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Predicitive failure notification:
Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification:
Warns when a battery is not available to provide backup power.
Audible alarms:
Provides notification of changing utility power and UPS power conditions
Protection
Frequency and voltage regulation:
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Power conditioning:
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction:
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible:
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Cold-start capable:
Provides temporary battery power when the utility power is out.
Resettable circuit breaker:
Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved:
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
- UPS topology
- Double-conversion (Online)
- Output power capacity
- 1 kVA
- AC outlet types
- C13 coupler
- Power plug
- C14 coupler
- Battery technology
- Sealed Lead Acid (VRLA)
- Number of battery cells
- 1
- Form factor
- Rackmount
- Rack capacity
- 2U